Przeglądanie stron 76
System Operation
© 2008 Microchip Technology Inc. DS70320B-page 73
A power meter is capable of measuring the input Power Factor of the SMPS AC/DC
Reference Design and also the Total Harmonic Distortion (THD) on the current drawn
by the system.
Using a programmable AC source will enable the user to evaluate the system
performance over the entire range of input voltage (85V-265V, 45Hz-65Hz).
4.2.2.2 OUTPUT PERFORMANCE TESTING
The SMPS AC/DC Reference Design can be loaded using DC electronic loads. A
number of output parameters can be tested by connecting oscilloscope probes to the
output terminals. Some of the parameters that can be tested are:
Output Ripple Voltage
Load Regulation
Transient Response
Step-Load Response
Fault Shutdown Delay
Przeglądanie stron 76